TM 5-2420-230-24-1
a. Removal.
Ensure air pressure is drained to 0 psi (0 kPa)
before taking off any air components. If pressure is
not released, components could blow off and harm
personnel. The IHMEE air system is pressurized
to 119 psi (820 kPa). Do not drain air from a tank
with any part of body in air spray path. Skin
embolisms and/or debris in eyes can occur from
released pressure. Failure to comply may result in
injury or death to personnel.
NOTE
Tag all hoses and tubes, and note their positions
before removal.
Remove cable ties as necessary.
High/low control cylinder is mounted on
backside of transmission.
(1)
Remove two air lines (1) from fittings (2).
(2)
Remove two fittings (2) from control cylinder (3).
(3)
Remove cotter pin (4) and pin (5) from clevis (6).
Discard cotter pin.
(4)
bracket (9), and control cylinder (3) from
(5)
Remove clevis (6) and nut (11) from control
cylinder (3).
(6)
Remove control cylinder (3) from bracket (9).
4-55
Change 1