TM 5-2420-230-24-2
Fan Pulley - Removal (0-9)
Section 0 - Engine Disassembly and Assembly - Group 00
Page 0-10
B Series Shop Manual
Fan Pulley - Removal (0-9)
13 mm
Remove the fan pulley and capscrews.
Vibration Damper/Crankshaft Pulley -
Removal (0-10)
15 mm
Remove the vibration damper or crankshaft pulley and
capscrews.
NOTE: Refer to Component Section 1 for the vibration
damper inspection procedure.
Belt Tensioner - Removal (0-11)
15 mm
Remove the belt tensioner from the bracket.
NOTE: Refer to Component Section 8 for the belt tensioner
inspection procedure..
5 mm Allen
Remove the tensioner bracket.