TM 5-2420-230-24-2
Injection Pump Timing - Bosch VE (5-08)
Section 5 - Fuel System - Group 05
Page 5-24
B Series Shop Manual
Continue to rotate the pump clockwise until the keyway is
preparing to align with the number one delivery valve.
Verify the gage is properly zeroed.
Continue rotating the pump clockwise while watching the
gauge. Count the revolutions. Each revolution equals 0.50
mm.
Three revolutions equal 1.50 mm. This illustration gives
an example of the indicator readings for the various
plunger lift values.
10 mm
Lock the pump at the desired plunger lift.
L-322