TM 5-2420-230-24-2
B3.9 and B5.9 Series Engines
Fuel Shutoff Valve (005-043)
Section 5 - Fuel System - Group 05
Page 5-69
The synchro-start has a Weather-Pack connector with three
wires in it.
Color
Description
Weather-Pack
Port
Black
Ground
C
White
Pull In
B
Red
Hold In
A
Wiring Guidelines:
Refer to the chart below to find the correct gauge size and
length of continuous wire for the white (pull-in) wire, which
This is the total wire length from the battery to the solenoid
and back to the battery. Both white and black wire lengh
must be added.
Length of Wire
Maximum Length in Feet
Gauge
cm
12 VDC
24 VDC
14
0 to 137
5
9
12
0 to 213
9
14
10
0 to 335
14
23
NOTE: Fourteen-gauge wire is required for the red (hold-in)
wire, which connects to the "Run" terminal on the ignition
switch.
NOTE: The black (ground) wire must be the same size as
the white (pull-in) wire.
Preparatory (005-043-000)
8 mm
Bosch VE
Remove the electrical wire, and complete the following
steps.
L-929