CLEAN FUEL TANK INLET SCREEN
CLEAN AIR CLEANER DUST UNLOADER VALVE

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  185    186    187    188    189  190  191    192    193    194    195  
img
TM 5-3805-280-10
Maintenance--As Required
CLEAN RADIATOR AIR INLET SCREENS
Remove wing nut (A) and pull up on handles (B) to slide
screens up for cleaning. Use pressurized air (30 psi max.)
or low pressure water.
TX,55,DH5565
­19­02JUL96­1/1
DRAIN WATER SEPARATOR
1. Open right access door to access water separator.
2. Open drain valve (A) and press pump (B) to extract
water from fuel system. Collect waste in a container
and dispose of it properly.
3. Close drain valve.
TX,55,DH5083
­19­02JUL96­1/1