TM 5-3805-281-24-2
Group 1740
Frame Installation
SPECIFICATIONS
Item
Measurement
Specification
Weld Metal
Tensile Strength
482.6 mPa (70,000 psi)
Yield Strength
413.7 mPa (60,000 psi)
Elongation
22%
38C (100F)
Structural Assembly
Preheat Temperature
177C (350F)
Ground Engaging Tool
Preheat Temperature
CED,OUOE003,1022 1922JUL981/1
WELDING ON MACHINE
IMPORTANT: Electrical current traveling from the
welder through the machine electrical
system may damage the machine
electrical system, including battery,
EPC controller. Disconnect battery
ground cable and EPC electrical
connectors before welding on the
machine.
Before welding on the machine, follow the steps listed
below to protect the machine electrical system.
TX,16,UU3320
1907JUL981/3
Continued on next page
17
1740