TM 5-3805-281-24-2
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR HYDRAULIC EXCAVATOR 330LCR
ITEM
INTERVAL
ITEM TO BE INSPECTED
EQUIPMENT IS NOT
NO.
PROCEDURE: DO THE PMCS AND HAVE ITEM
READY/AVAILABLE
REPAIRED, FILLED, OR ADJUSTED AS NEEDED
IF:
(15) Clean inside of tank and suction filter.
(16) Change hydraulic oil filter. (Refer to Quarterly
services.)
(17) Change pilot control oil filter. (Refer to Semi-
Annual services.)
(18) Install suction screen with cover. Suction
screen must seal against outlet pipe in bottom
of tank. If necessary, loosen nut (B) to adjust
rod length.
SPECIFICATIONS
Suction Screen Rod Length (A)
702 mm (26.4 in.)
17 Nm (12.5 lb-ft)
Top of Rod to Top of Rod Nut (C) 20 mm (0.8 in.)
49 Nm (36 lb-ft)
(19) Install tank drain plug and bottom guard.
(20) Add oil until it is between marks on sight glass
CAUTION: If the hydraulic pump is not filled
with oil, it will be damaged when the engine is
started.
A-28