C 1, SB 740-97-38
Classification
Major
Minor
Item
Defect
A
B
ATTACHMENTS:
Refer to SB 740-97-1
MISCELLANEOUS
COMPONENTS:
Painted
Stage III corrosion............................................................................................................
X
Unpainted noncritical
Stage III corrosion............................................................................................................
X
OUTRIGGERS:
Manually operated
Stage III corrosion on pads or jack screws ......................................................................
X
Hydraulically operated
Stage III corrosion on cylinder assembly .........................................................................
X
SHEAVES:
Frozen .............................................................................................................................
X
ETHER DISCHARGER:
Stage IV corrosion on internal surfaces ..........................................................................
X
Stage III corrosion on internal surfaces; broken or distorted spring;
rubber washer distorted or deteriorated .....................................................................
X
Stage II corrosion on internal surfaces ...........................................................................
X
WINTERIZATION SYSTEM:
Heater
Stage IV corrosion on interior surfaces............................................................................
X
Stage III corrosion on interior surfaces ............................................................................
X
Stage II corrosion on interior surfaces ............................................................................
X
Fuel system
Stage IV corrosion on interior surface of pump ............................................................... X
Stage III corrosion on interior surface of pump; cracks, breaks or
kinks in lines; filter contaminated .................................................................................
X
Stage II corrosion on interior surface of pump ................................................................
X
MODIFICATION WORK
ORDER (MWO):
Urgent classification
Not applied ......................................................................................................................
X
Routine classification
Not applied ......................................................................................................................
X
EQUIPMENT LOG BOOK
(TM 38-750):
Missing ............................................................................................................................
X
Incomplete ......................................................................................................................
X
DATA PLATES:
Illegible or missing ..........................................................................................................
X
WARNING OR CAUTION
PLATES:
Illegible; missing .............................................................................................................
X
A-DEPRESERVATION GUIDE
(DA FORM 2258):
Illegible or missing ..........................................................................................................
X
III-B-5