C 2, SB 740-97-38
APPENDIX III-O
ITEM DEFECTS FOR KETTLE, HEATING, BITUMEN
Classification
Item
Defect
Major
Minor
AB
Brackets and hangers
Stage IV corrosion: cracked or broken ............................................................... X
Stage III corrosion ...............................................................................................
X
Stage II corrosion ................................................................................................
X
Stage IV corrosion: punctured............................................................................ X
Stage III corrosion ...............................................................................................
X
Stage II corrosion ................................................................................................
X
ELECTRICAL SYSTEM:
Wiring
Broken strands: cracked insulation: fungus growth........................................... X
Frayed: checked: loss of flexibility .....................................................................
X
Terminals and connections
Stage III corrosion: broken terminals.................................................................. X
Stage II corrosion ................................................................................................
X
Spark plugs
Stage III corrosion on spark point end; ceramic insulator
broken .................................................................................................................
X
Stage II corrosion on spark point end..................................................................
X
Switches and magnetos
Stage III corrosion; broken: frozen ..................................................................... X
Stage II corrosion ................................................................................................
X
Stage III corrosion: cracked or broken................................................................
X
Stage II corrosion ................................................................................................
X
LUBRICATION SYSTEM:
Lines. hoses and fittings
Kinked: broken: leaks or seeps: checked or cracked: fungus
growth ................................................................................................................. X
Filters
Stage III corrosion on internal or external surfaces ............................................. X
Stage II corrosion on internal surfaces: element deteriorated or
contaminated.......................................................................................................
X
Lubricant
Contaminated......................................................................................................
X
Seals
Deteriorated; leaks or seeps................................................................................
X
CONTROLS AND INSTRUMENTS:
Stage III corrosion: cracked or broken; inoperable; dial face
illegible ................................................................................................................ X
Stage II corrosion: linkage frozen .......................................................................
X
BURNER SYSTEM:
Burner assembly
Stage III corrosion on internal surfaces; breaks or leaks..................................... X
Stage II corrosion on internal surfaces................................................................
X
Fuel tank:
Internal surfaces
Stage III corrosion: contaminated....................................................................... X
Stage II corrosion ................................................................................................
X
Pump
Stage III corrosion on internal surfaces; bent, cracked or
inoperative; valves deteriorated ........................................................................... X
Stage II corrosion on internal surfaces................................................................
X
Hose or tubing
Cracked or broken; kinked: frayed: deteriorated ................................................ X
Gages
Glass broken or discolored; dial faces deteriorated;
inoperable............................................................................................................ X
Burner nozzle
Stage III corrosion; clogged................................................................................. X
Stage II corrosion ................................................................................................
X
Thermostat
Bent, broken or inoperative.................................................................................. X
Valves and regulator
Stage III corrosion on internal surfaces; bent or broken;
inoperative........................................................................................................... X
Stage II corrosion on internal surfaces................................................................
X
BRAKE ASSEMBLY:
Drum and/or shoes
Stage IV corrosion............................................................................................... X
Stage III corrosion ...............................................................................................
X
Stage II corrosion ................................................................................................
X