C 4, SB 740-97-38
APPENDIX III-X
ITEM DEFECTS FOR HEATER, CONCRETE MIXER
Classification
Item
Defect
Major
Minor
A
B
EXTERIOR SURFACES AND
HOUSINGS:
General
Fractures; , ase moullntind anl or fastening devices broken or missing
x
Dents
............................................................................................................. x
Painred surface
Stage II corrosion: chippeil or liradld.....................................................
x
Stage II corrosion
............................................................................................................. x
Unpainted noncritical surfaces
Stage IV corloson .....................................................................................
x
Stage III corrono
............................................................................................................. x
Stage II Corrosion
.............................................................................................................
x
Frame and shell assembly
Stage IV corrosion on interior surfaces of inner
and/or outer jacket; bent, broken, dneted, or distorted......................................................................................
x
Stage III corrosion on interior surfaces of inner
and;or outer jacket
............................................................................................................. x
Conical head and damper
assembly.
Stage IV corrosion on interior surfaces; bent,
cracked, or broken; frozen
x
Stage III corrosion on interlol surfaces .............................................................................................................
x
Lifting handles and lifting
attachments
Bent, cracked. bloken. or distorted; stage IV corrosion ....................
x
Stage III corrosion
............................................................................................................. x
Piping and fittings
Stage IV conrrosion on interior surfaces; leaks,
breaks, or I)end.s; damiaaged threads ............................................................................................................. x
Stage III c(orrosion on interior surfaces .............................................................................................................
x
Burner door and platform
assembly
Bent, broken, or dlentted; stage IV corrosion on hinges.....................
x
Stage III corrosion on hinges
............................................................................................................. x
Stage II corrosion hlinges
.............................................................................................................
x
Drain and/or air release
valve.
Stage IV conroslon ma interior surfaces; handwheel
broken; steim bent or frozen; leaks
x
Stage III c(orrosion on interior sulfaces .............................................................................................................
x
Stage II corrosion on interior surfaces .............................................................................................................
x
Safety valve
Stage IV cmi'oslon on interior surfaces; leaks .....................................
x
Stage III corrosion on interior surfaces .............................................................................................................
x
Stage II corrosion on interior surfaces .............................................................................................................
x
Water coils
Bent, cracked. broken., ordistorted; stage IV corrosion.....................
x
Stage III corrosion
............................................................................................................. x
Water tank
Stage I V cotnoslon of interior or exterior surfaces .............................
x
Stage III coTrosion of interior or extenor
surfaces; interior contaminated tith dirt, sludge,
or other foreign matter
............................................................................................................. x
Stage II corrosion of interior or exterior surfaces...............................................................................................
.
x
BURNER ASSEMBLY:
Burner shell
Bent, broken or distorted; stage IV corrosion ......................................
x
Stage III corrosion
............................................................................................................. x
Burner needle valve
Stage IV corrosion on intenor surfaces; stem bent
or fiozen; leaks; strainer punctured, tom or distorted........................................................................................
x
Stage III corrosion on intenor surfaces;
contaminated
............................................................................................................. x
Stage II corrosion on interior surfaces .............................................................................................................
x
FUEL TANK ASSEMBLY:
Tank
Stage IV corroslon on interior surfaces; fill
cap gasket deteriorated
x
Stage III corrosion on interior surfaces; interior
contamlna', ld wilth dirt, sludge, or other foreign matter ...................................................................................
x
III-X-0