TM 5-2420-232-10
0036
OPERATION
0036
1.
Observe all WARNINGs.
2.
Move hydraulic circuit control valve to ON position.
3.
Place tool bit firmly on surface to be broken.
NOTE
Partially depressing trigger allows tool to operate at low speed, making it easy to start tool bit into
surface to be broken.
4.
Squeeze trigger (Figure 1, Item 1) to start the breaker. Adequate down pressure is very important.
435-A1362
Figure 1. Pavement Breaker
036
COLD WEATHER OPERATION
0036
If breaker is to be used during cold weather, preheat hydraulic fluid at low engine speed. When using normally recommended
fluids, fluid temperature should be at or above 50 F (10C) before use.
Good maintenance practices will keep the breaker on the job and increase its service life.
A very important maintenance practice is to keep the hydraulic fluid clean at all times. Contaminated hydraulic fluid causes
rapid wear and/or failure of internal parts.
END OF WORK PACKAGE
0036-3/(4 Blank)