OPERATOR STATION CHECKS--KEY SWITCH ON, ENGINE OFF
OPERATOR STATION CHECKS--KEY SWITCH ON, ENGINE OFF - Continued

Maintenance Manual For Hydraulic Excavator Model 230Lcr
Page Navigation
  44    45    46    47    48  49  50    51    52    53    54  
img
TM 5-3805-280-24-1
Operational Checkout Procedure
YES: Go to next check.
FLUID LEVEL
A--Level Check Switch
(COOLANT, HYDRAULIC
B--Engine Oil Level Indicator
OIL, AND ENGINE OIL)
C--Engine Coolant Level Indicator
NO: Check monitor fuse.
INDICATOR CIRCUIT
D--Hydraulic Oil level Indicator
If OK, check fluid levels in
CHECKS
radiator, recovery tank,
hydraulic oil tank, or
Engine OFF.
9005
engine. If OK, check fluid
10
level switch or wiring. Go
Key switch ON.
3
to Group 9015-15.
Push and hold level check switch (A).
Are the hydraulic oil level (D), coolant level (C), and
engine oil level (B) indicator lights ON?
T102097 UN26JUL96
1/1
2-3