RADIATOR AIR FLOW TEST
JTO5529 AIRFLOW METER TEST RECORD

Maintenance Manual For Hydraulic Excavator Model 230Lcr
Page Navigation
  136    137    138    139    140  141  142    143    144    145    146  
img
TM 5-3805-280-24-1
Tests
8. Put air flow meter against the trash screen so it is
centered in a square and air flow is through meter in
the direction of air flow arrow.
9. Record voltage reading for each square that is not
marked out with an "X".
NOTE: Make a copy of the JT05529 Air Flow Meter Test
Record shown on the following page. Use to
make a record of the voltage readings and
machine information.
9010
25
5
10. Add the voltage readings. The total of readings must
be equal to or greater than the specification.
Air Flow Meter Total Reading Equal to or Greater Than--
Specification
Voltage........................................................................ 5.10 V (typical new)
11. If readings are less than specification, clean the trash
screen and external surfaces of oil cooler and
radiator. Repeat test.
Continued on next page
CED,OUOE003,1058 1912AUG983/4