DIAGNOSE BATTERY MALFUNCTIONS
CHECK BATTERY ELECTROLYTE LEVEL AND TERMINALS - CONTINUED

Maintenance Manual For Hydraulic Excavator Model 230Lcr
Page Navigation
  299    300    301    302    303  304  305    306    307    308    309  
img
TM 5-3805-280-24-1
References
CHECK BATTERY ELECTROLYTE LEVEL
AND TERMINALS
CAUTION: Battery gas can explode. Keep
sparks and flames away from batteries. Use a
flashlight to check battery electrolyte level.
Never check battery charge by placing a metal
object across the posts. Use a voltmeter or
hydrometer.
Always remove grounded (-) battery clamp first
and replace it last.
Sulfuric acid in battery electrolyte is poisonous.
9015
It is strong enough to burn skin, eat holes in
20
clothing, and cause blindness if splashed into
4
eyes.
Avoid the hazard by:
1. Filling batteries in a well-ventilated area.
2. Wearing eye protection and rubber gloves.
3. Avoiding breathing fumes when electrolyte is
added.
4. Avoiding spilling or dripping electrolyte.
5. Use proper jump start procedure.
If you spill acid on yourself:
1. Flush your skin with water.
2. Apply baking soda or lime to help neutralize
the acid.
3. Flush your eyes with water for 10--15
minutes. Get medical attention immediately.
If acid is swallowed:
1. Drink large amounts of water or milk.
2. Then drink milk of magnesia, beaten eggs, or
vegetable oil.
3. Get medical attention immediately.
1. Remove hold-down clamps.
2. Remove battery covers.
Continued on next page