• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
EVACUATE R134A SYSTEM - Continued
CHARGE R134A SYSTEM

Maintenance Manual For Hydraulic Excavator Model 230Lcr
Page Navigation
  616    617    618    619    620  621  622    623    624    625    626  
img
TM 5-3805-280-24-1
Adjustments
9. Open low-side and high-side valves.
10. Evacuate system for 30 minutes after 98 kPa (980
mbar) (29 in. Hg) vacuum is reached.
Evacuate System--Specification
Time............................................................ For 30 min. After 98 kPa (980
mbar) (29 in. Hg) Vacuum
11. Close low-side and high-side valves. Stop evacuation.
12. Charge the system. (See procedure in this group.)
CED,TX14795,4341
1918AUG983/3
9031
20
9
7-30


Privacy Statement