• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
ACCESSORY CIRCUITS DIAGNOSTIC PROCEDURES
QUICK HITCH CIRCUIT OPERATIONAL INFORMATION

Technical Manual For Hydraulic Excavator Model 330Lcr 1
Page Navigation
  238    239    240    241    242  243  244    245    246    247    248  
img
TM 5-3805-281-24-1
Sub-System Diagnostics
YES: Relay is OK.
HORN RELAY (K5)
1--24-Volt Terminal
CHECK
2--Ground Terminal
3--Relay Common
NO: Relay has failed.
4--Relay Normally Closed
Replace.
5--Relay Normally Open
Disconnect harness from relay.
Connect ohmmeter to terminals 3 and 4.
T7447BG
1914JAN91
Does ohmmeter read continuity?
Connect 24 volts to relay terminal 1 and ground terminal
2.
Does relay "click"?
With 24 volts still connected to terminal 1, connect
ohmmeter to terminals 3 and 5.
9015
15
Does ohmmeter read continuity?
40
1/1
HORN SWITCH (S2)
YES: Horn switch OK.
CHECK
Check wiring harness and
horns.
NO: Replace switch.
T108586 UN31MAR97
Remove bottom cover from left arm rest.
Disconnect wire harness from horn switch.
Connect ohmmeter to both wires (pink and black) and push horn button.
Does ohmmeter read continuity?
1/1