HYDRAULIC PUMP REGULATOR TEST AND ADJUSTMENT--MINIMUM FLOW
HYDRAULIC PUMP REGULATOR TEST AND ADJUSTMENT--MINIMUM FLOW - Continued

Technical Manual For Hydraulic Excavator Model 330Lcr 1
Page Navigation
  605    606    607    608    609  610  611    612    613    614    615  
img
TM 5-3805-281-24-1
Tests
4. Heat hydraulic oil to the specified temperature. (See
Hydraulic System Warm-Up Procedure in this group.)
Hydraulic Oil--Specification
Temperature ........................................................... 50 5C (120 10F)
5. Stop the engine.
CED,TX08227,3141
1928MAY982/5
6. Loosen vent plug (K) to release the air pressure in
hydraulic oil tank.
9025
K--Vent Plug
25
105
Continued on next page
CED,TX08227,3141
1928MAY983/5
6-252