DISCONNECTING TAB RETAINER CONNECTORS
FUSE (BLADE-TYPE) COLOR CODES

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  529    530    531    532    533  534  535    536    537    538    539  
img
TM 5-3805-281-24-2
Wiring Harness and Switches
IMPORTANT: Install fuse with correct amperage
rating to prevent electrical system
damage from overload.
1--5 Amp Backup
2--10 Amp Controller
3--10 Amp EC Motor
4--5 Amp Solenoid
5--10 Amp Power On
6--5 Amp Switch Box
7--5 Amp Option 1
8--10 Amp Option 2
9--5 Amp Option 3
10--5 Amp Travel (Alarm)
11--20 Amp Lamp
12--10 Amp Wiper (Windshield and Washer)
13--20 Amp Heater
14--5 Amp AirCon (Air Conditioning)
15--10 Amp Horn
16--5 Amp Radio
17--10 Amp Lighter
18--5 Amp Room Lamp (Dome Light)
19--10 Amp Auxiliary
20--20 Amp Start Aid