TM 5-3805-281-24-2
Hydraulic Impact Breaker
33
1--Upper Shock Absorber
4--Top Cap Lock Nut
8--Wear Plate Shim .036
11--Casing
53
2--Shock Absorber Holder
5--Side Shock Absorber
in. or .048 in.
3--Top Cap Bolt and
6--Shock Absorber Bolt
9--Wear Plate
Washer
7--Disk Lock Washer
10--Grease Nipple
5. Measure clearance between breaker and case.
ASSEMBLE BREAKER CASE AND MOUNTING
BRACKET
6. Assemble shock absorber holder (2) and upper
shock absorber (1).
1. Install wear plate (9) and shims (8).
7. Install grease fitting (10) into case (11).
2. Slide breaker into casing (11).
8. Install top shock absorber (1), holder (2) and the
3. Push breaker deep inside casing. Check breaker for
mounting bracket onto casing with screws (3) and
proper clearance per specification and shim as
self-locking nuts (4). Tighten to proper torque
required.
specification.
4. Assemble side shock absorbers (5) with Allen
wrench and tighten to proper torque specification.
Continued on next page
CED,OUOE039,6 1920MAR9932/37
20-49