TM 5-3805-281-24-2
Electrical System and Electrical Engine Controls
REPLACE (PUSH TYPE) METRI-PACKTM
CONNECTORS
Disconnect the METRI-PACKTM connector. Remove the tie
bands and tape.
Remove the connector lock (A), and mark wire colors for
identification.
Identify wire color locations with connector terminal letters.
Insert JDG776 or JDG777 Terminal Extraction Tool (B)
Replacing (Push Type) METRI-PACKTM Connectors
into connector body socket (C) pushing the terminal
locking tab inward.
A--Connector Lock
B--Extraction Tool JDG771
NOTE: Use JDG776 Extraction Tool with 56, 280 and 630
C--Connector Body Socket
series METRI-PACKTM terminals. Use JDG777
D--Terminal
E--Locking Tab
Extraction Tool with 150 series METRI-PACKTM
terminals.
Remove extraction tool and pull terminal (D) out of the
socket.
Replace terminal. Make sure locking tab (E) on the new
terminal is in the outward position.
Push terminal into connector body socket until terminal
locks.
METRI-PACK is a trademark of Packard Electric.
1
Included in JT07195A Electrical Repair Kit
RG,RG34710,1334
1923OCT971/1
USE ELECTRICAL INSULATING COMPOUND
Apply AT66865 Compound directly to the terminals
between the wire seal and connector body. This provides
a moisture barrier, especially in wet and humid conditions.
RG,RG34710,1335
1923OCT971/1