TM 5-3805-281-24-2
Hydraulic System
8. Check to be sure spring (G) remains in position when
33
3360
9. Tighten cap screws (A).
71
Solenoid Valve Housing-to-Manifold Cap Screw--Specification
Torque .............................................................................. 3 Nm (24 lb-in.)
A--Cap Screw (2 used)
F--Solenoid Coil
G--Spring
TX,33,GG2414 1917DEC965/5
REMOVE AND INSTALL DIG FUNCTION
PILOT CONTROLLER
CAUTION: The hydraulic oil tank is pressurized.
High pressure release of oil from pressurized
system can cause serious burns or penetrating
injury. Release pressure from tank by loosening
vent plug. It is not necessary to remove vent
plug.
1. Loosen vent plug (A) to release air pressure from
hydraulic oil tank.
A--Vent Plug
Continued on next page
CED,OUOE027,310
1905JUN981/6