TM 5-2420-230-24-2
Injection Pump Repairs - Lucas CAV DPA (5-09)
Section 5 - Fuel System - Group 05
Page 5-32
B Series Shop Manual
Lift off the lever while allowing the return spring to unwind.
Position the return spring with one end of spring contact-
ing the boss on the governor cover.
Hook the free end around the shut off lever and rotate the
lever in a clockwise direction until it engages with the flats
on the shut off shaft.
8 mm
Install the nut with a new lock washer.
[30 in-lb]
L-330