Shutdown Solenoid - Replacement (5-12)
Vent Fitting/Sealing Washer - Inspection/Replacement (5-14)

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  320    321    322    323    324  325  326    327    328    329    330  
img
TM 5-2420-230-24-2
Injection Pump Repairs - Lucas CAV DPA (5-09)
Section 5 - Fuel System - Group 05
Page 5-28
B Series Shop Manual
Inspect the plunger tip. If the tip is damaged or deformed,
replace the solenoid assembly.
22 mm
Install the plunger, spring, solenoid and o-ring.
Torque Value: 15 Nm
[11 ft-lb]
Bleed Screws/Sealing Washers - Replace-
ment (5-13)
8 mm, 11 mm
Remove the screw, fitting and washer.
Inspect the threads and sealing surfaces.
If the fitting or bleed screw is damaged, replace the dam-
aged components.
L-326