TM 5-2420-230-24-2
Injection Pump Repairs (5-21)
Section 5 - Fuel System - Group 05
Page 5-42
B Series Shop Manual
Install new insulating tubes onto the terminal studs of the
new solenoid. Apply dielectric grease to the terminal studs
and to the area the solenoid will come into contact with
the top cover.
Install the solenoid to the top cover.
[12 ft-lb]
Use the Stanadyne ETR solenoid arm retaining tool to
make sure the arm is in the correct position during the top
cover installation.
Install the top cover and gasket to the injection pump.
Twist the retaining tool to release it from the arm. Slide the
tool out from between the top cover and pump.
[41 in-lb]
L-340