TM 5-2420-230-24-2
Section 7 - Lubrication Oil System - Group 7
Page 7-14
B Series
Clean all parts in solvent and use compressed air to dry.
Inspect the pump housing and gerotor drive for damage
and excessive wear.
Be sure the gerotor planetary is installed in the origi-
nal position.
Install the gerotor planetary.
Measure the tip clearance.
Tip Clearance
mm
in
0.1778
MAX
[0.007]