TM 5-2420-230-24-2
Engine Storage - Long Term (14-10)
Section 14 - Engine Testing - Group 14
Page 14-36
B Series Shop Manual
Remove the lubricating oil filter. Install a new filter ac-
cording to the manufacturer's specifications.
Pressure fill the engine with 15W40 lubricating oil through
the 1.8 inch pipe tap on the side of the oil filter housing
directly below the turbocharger oil supply connection.
Use 207 kPa (30 psi) to pressure fill the system with a
minimum of 3.6 L (1 U.S. gal).
Reinstall the drain plug and fill the oil pan to the high mark
on the dipstick.
Caution: Make sure the engine does not start when you
crank the engine by disconnecting the fuel solenoid or
positioning the shut down lever in the stop position.
Use the starter to crank the engine for a maximum of 30
seconds, with two minute intervals, until oil pressure reg-
isters on the lubricating oil pressure gauge.
L-466