Install the expanding plug in the barring tool hole.
Coat both sides of the inspection plate gasket with KW
Copper Coat .
13 mm
Install the inspection plate.
Tighten to 24 Nm [18 ft-lbs].
Wet Clutch Application
Perform all the steps in the procedure for dry clutch in-
stallation in addition to the following:
Coat the flywheel housing drain plug with pipe sealant
and install in the hole in the bottom of the flywheel hous-
ing.
Tighten the plug.
Refer to the pipe plug torque values in Section 10 for
different plug sizes.