TM 5-3805-280-10
Maintenance--As Required
CLEAN RADIATOR AIR INLET SCREENS
Remove wing nut (A) and pull up on handles (B) to slide
screens up for cleaning. Use pressurized air (30 psi max.)
or low pressure water.
TX,55,DH5565
1902JUL961/1
DRAIN WATER SEPARATOR
1. Open right access door to access water separator.
2. Open drain valve (A) and press pump (B) to extract
water from fuel system. Collect waste in a container
and dispose of it properly.
3. Close drain valve.
TX,55,DH5083
1902JUL961/1
11-4