TM 5-3805-280-24-2
30
INTERNAL CENTER HOUSING
12
1. Using a flashlight, look through the oil return hole (A),
to check the condition of the shaft and/or bearings.
There should not be excess carbon deposits on the
shaft or in the housing.
A--Oil Return
RG,30,JW7574
1920NOV979/13
2. Excessive "blueing" or "coking" of oil along the
complete length of the shaft indicates a possible lack
of lubrication caused by an engine failure, or improper
operation, such as hot shutdowns.
RG,30,JW7574
1920NOV9710/13
TURBOCHARGER BENCH TEST
1. Mount the turbocharger in a vise.
2. Rotate the shaft, using both hands, to check rotation
and clearance. The shaft should turn freely, however,
there may be a slight amount of drag.
Continued on next page
RG,30,JW7574
1920NOV9711/13
13-368