R134A COMPONENT OIL CHARGE
RECOVER R134A SYSTEM

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  786    787    788    789    790  791  792    793    794    795    796  
img
TM 5-3805-280-24-2
Heating and Air Conditioning
R134A REFRIGERANT RECOVERY,
RECYCLING AND CHARGING STATION
INSTALLATION PROCEDURE
CAUTION: Do not remove high pressure relief
valve (B). Air conditioning system will
discharge rapidly causing possible injury.
IMPORTANT: Use correct refrigerant recovery,
recycling and charging stations. DO
NOT mix refrigerant, hoses, fittings,
components or refrigerant oils.
1. Close both high and low pressure valves on refrigerant
recovery, recycling and charging station (J).
2. Remove cap from low pressure test port (A).
3. Connect low pressure blue hose (G) from refrigerant
recovery, recycling and charging station (J) to low
pressure test port (A) on compressor.
4. Connect high pressure red hose (I) to high pressure
quick disconnect (F).
5. Follow the manufactures instructions when using the
refrigerant recovery, recycling and charging station.
A--Low Pressure Test Port
B--High Pressure Relief Valve
C--Low Pressure Hose
D--Low Pressure Switch
E--High Pressure Switch
F--High Pressure Quick-Disconnect
G--Blue Hose
H--High Pressure Hose
I--Red Hose
J--Refrigerant Recovery/Recycling and Charging
Station
18