2 OPERATOR STATION CHECKS--ENGINE ON
1/1
MONITOR CIRCUIT,
A--Coolant Temperature Gauge Needle
YES: Go to next check.
GAUGE CHECKS
B--Fuel Gauge
NO: Check alternator belt
if battery light is on after
Start engine.
engine starts. Go to your
authorized dealer.
Are all monitor indicator lights OFF after engine starts?
Is coolant temperature gauge needle (A) in normal
operating zone after a few minutes?
Does fuel gauge (B) indicate fuel level?
Stop engine.
T107698 UN27FEB97
1/1
POWER MODE CIRCUIT
A--High Power Mode Switch
YES: Go to next check.
CHECKS
B--Economy Mode Switch
NO: Check controller
Start engine.
fuse. Go to your
authorized dealer.
Auto-idle switch OFF.
Propel speed switch in fast position.
Pilot shut-off lever in LOCKED position.
Push power mode select switches (A) and (B) one at a
time.
Do corresponding indicator lights come on as each
switch is pushed?
T102098 UN26JUL96