CHECK BATTERY ELECTROLYTE LEVEL AND TERMINALS
PROCEDURE FOR TESTING BATTERIES

Technical Manual For Hydraulic Excavator Model 330Lcr 1
Page Navigation
  304    305    306    307    308  309  310    311    312    313    314  
img
TM 5-3805-281-24-1
References
IMPORTANT: During freezing weather, batteries must
be charged after water is added to
prevent battery freezing. Charge battery
using a battery charger or by running
the engine.
3. Fill each cell to within specified range with distilled
water. DO NOT overfill.
Single Level Fill Tube Application
9015
20
5
Dual Level Fill Tube Application
A--Battery Post
B--Fill Tube
C--Electrolyte Level Range
TX,16,UU3540