• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
ARCTIC/COLD WEATHER HEATER CHECKS
Function and Fault Test Chart

Technical Manual For Hydraulic Excavator Model 330Lcr 1
Page Navigation
  690    691    692    693    694  695  696    697    698    699    700  
img
.
TM 5-3805-281-24-1
Group 15
Diagnostic Information
DIAGNOSE ARCTIC/COLD WEATHER
HEATER MALFUNCTIONS
In the event of a malfunction, the following items should
be checked before performing the heater diagnostic
procedure:
Fuel supply
Fuses, electrical lines and connections.
Battery voltage.
Coolant flow.
Interference in the combustion air and exhaust pipes
If combustion is sooty, check the following:
combustion air and exhaust ducts. Clear if necessary.
Fuel metering pump. Measure for excessive delivery,
and replace if necessary.
CED,OUOE012,179
1916APR991/1
ARCTIC/COLD WEATHER HEATER
DIAGNOSTIC PROCEDURE
The heater system utilizes the green LED light located
next to the arctic/cold weather heater switch, located on
the right hand console inside the cab, to provide fault
information. The light provides different illumination
sequences depending on the malfunction as shown in the
function and fault test chart.
9035
15
1
Continued on next page
CED,OUOE012,181
1916APR991/3
8-7


Privacy Statement
Press Release
Contact