CHECKING ELECTROLYTE SPECIFIC GRAVITY
CHECK BATTERY ELECTROLYTE LEVEL AND TERMINALS

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  496    497    498    499    500  501  502    503    504    505    506  
img
TM 5-3805-281-24-2
Batteries, Support, and Cables
Follow directions included with the tester.
A fully charged battery will have a corrected specific
gravity reading of 1.260. If the reading is below 1.200,
charge the battery.
NOTE: In tropical areas, use 1.225 for the full charge
reading. In cold areas, use 1.280 for the
full-charge reading.