• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 330LCR - Continued
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES FOR HYDRAULIC EXCAVATOR 330LCR - Continued

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  1010    1011    1012    1013    1014  1015  1016    1017    1018    1019    1020  
img
TM 5-3805-281-24-2
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES
FOR HYDRAULIC EXCAVATOR 330LCR
ITEM
INTERVAL
ITEM TO BE INSPECTED
EQUIPMENT IS NOT
NO.
PROCEDURE: DO THE PMCS AND HAVE ITEM
READY/AVAILABLE
REPAIRED, FILLED, OR ADJUSTED AS NEEDED
IF:
WARNING: Prevent possible injury from
flying chips if compressed air is more than
210 kPa (2.1 bar) (30 psi). Reduce compressed
air to less than 210 kPa (2.1 bar) (30 psi)
when using for cleaning purposes. Clear area
of bystanders, guard against flying chips, and
wear personal protection equipment including
eye protection.
NOTE: Remove element and inspect for metal
particles and debris in bottom of filter case.
Excessive amounts of brass and steel particles
can indicate a hydraulic pump, motor, or
valve malfunction, or a malfunction in
progress. A rubber type of material can
indicate cylinder-packing problem.
(14) Clean filter case with diesel fuel and dry with
compressed air.
(15) Install filter case, valve (E), and spring (C) in
reservoir.
(16) Install cover (A) and tighten cap screws (B).
FILTER COVER SPECIFICATIONS
49 Nm (36 lb-ft)
Cap Screws, Cover
(17) Tighten vent plug.
A-17


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.