• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. DTC 105.04 - Manifold Air Temperature Signal Out of Range Low - Continued.
DTC 105.15 - MANIFOLD AIR TEMPERATURE SIGNAL SLIGHTLY HIGH

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  179    180    181    182    183  184  185    186    187    188    189  
img
TM 5-3805-294-23-1
0027
Table 1. DTC 105.04 - Manifold Air Temperature Signal Out of Range Low - Continued.
Test or Inspection
Corrective Action
Malfunction
5.
Turn the key switch to the OFF
1.
If DTC 105.04 is still active, it is
position (TM 5-3805-294-10).
possible that another fault
exists or that another
(Volume 5, WP 0794)
troubleshooting procedure
applies. If this was the first time
through this procedure, restart
procedure at Malfunction 1.
2.
If DTC 105.04 is not active,
problem corrected. Restore
machine to original condition.
END OF WORK PACKAGE
0027-10


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.