• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. DTC 174.16 - Fuel Temperature Signal Moderately High - Continued.
Table 1. DTC 174.16 - Fuel Temperature Signal Moderately High - Continued.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  302    303    304    305    306  307  308    309    310    311    312  
img
TM 5-3805-294-23-1
0045
Table 1. DTC 174.16 - Fuel Temperature Signal Moderately High - Continued.
Test or Inspection
Corrective Action
Malfunction
8.
Under ECU - (shown with
engine serial number), select
ECU - Data List - All. (Volume
3, WP 0363)
9.
Under ECU - Data List - All,
select Fuel Temperature.
(Volume 3, WP 0363)
10.
Monitor the fuel temperature
sensor temperature.
Temperature should closely
match ambient air
temperature. Note reading.
11.
When finished monitoring,
select Readings and select
Disconnect From Model(s).
(Volume 3, WP 0363)
12.
Select Yes to terminate your
readings connection. (Volume
3, WP 0363)
13.
Turn key switch to OFF
1.
If sensor closely matched
position (TM 5-3805-294-10).
ambient air temperature,
proceed to Malfunction 11.
(Volume 5, WP 0794)
2.
If sensor does not closely
match ambient air temperature
and fuel temperature sensor
was previously replaced,
proceed to Malfunction 8.
3.
If sensor does not closely
match ambient air
temperature, replace fuel
temperature sensor. (Volume
3, WP 0430) Restore machine
to original condition. Operate
engine through normal speed
and load (TM 5-3805-294-10).
(Volume 5, WP 0794) Clear
and refresh DTCs. (Volume 3,
WP 0362)
0045-5


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.