Table 1. DTC 653.06 - Injector #3 Circuit Has Low Resistance - Continued.
DTC 653.07 - INJECTOR #3 NOT RESPONDING

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  524    525    526    527    528  529  530    531    532    533    534  
img
TM 5-3805-294-23-1
0077
Table 1. DTC 653.06 - Injector #3 Circuit Has Low Resistance - Continued.
Test or Inspection
Corrective Action
Malfunction
1.
Turn key switch to ON position,
10.
Short Circuit
but DO NOT START ENGINE
Between Engine
(TM 5-3805-294-10). (Volume
Wiring Harness
Connector J01
5, WP 0794)
Socket D1 and
Ground.
2.
Measure voltage (Volume 3,
WP 0369) between engine
wiring harness connector J01
socket D1 (Volume 5,
WP 0800, Figure 46) and a
known good ground. Note
reading.
3.
Turn key switch to OFF
1.
If voltage is less than 0.5 volts,
position (TM 5-3805-294-10).
replace ECU. (Volume 4,
(Volume 5, WP 0794)
WP 0508) Restore machine to
original condition and perform
Harness Diagnostic Mode
Test. (Volume 3, WP 0345)
2.
If voltage is greater than 0.5
volts, replace engine wiring
harness. (Volume 4,
WP 0510) Restore machine to
original condition and perform
Harness Diagnostic Mode
Test. (Volume 3, WP 0345)
END OF WORK PACKAGE
0077-7/8 blank