Table 3-6. Unit Troubleshooting Table.
EXCESSIVE EXHAUST NOISE OR RATTLING.

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  63    64    65    66    67  68  69    70    71    72    73  
img
. . .
TM 5-2420-230-24-1
Table 3-6. Unit Troubleshooting Table. -- Continued
Malfunction
Test or Inspection
Corrective Action
ENGINE CRANKS BUT WILL NOT START. -- CONTINUED
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical circuits, a
direct short may result. Damage to equipment and injury or death to personnel may occur.
Step 6.
Check fuel shut-off solenoid (5) to ensure it is functioning properly.
If fuel shut-off solenoid arm (6) moves, notify Direct Support maintenance (Appendix L).
Step 7.
Check wiring harness (7) for continuity and connector (8) for damage or short.
If wiring harness (7) does not have continuity, replace wiring harness (Para 12-27).
If connector (8) has damage or a short, replace connector (Para 12-28).
Step 8.
Check wiring harness from fuel shut-off solenoid to power source for continuity.
If wiring harness does not have continuity, replace wiring harness (Para 12-27).
If fault continues, notify Direct Support maintenance (Para L-26).