• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
USING BOOSTER BATTERIES--24 VOLT SYSTEM
STARTING FLUID (COLD WEATHER STARTING AID)

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  75    76    77    78    79  80  81    82    83    84    85  
img
TM 5-3805-280-10
Operating the Engine
SLAVE RECEPTACLE--24 VOLT SYSTEM
Before boost starting, machine must be properly shut
down to prevent unexpected machine movement when
engine starts.
CAUTION: An explosive gas is produced while
batteries are in use or being charged. Keep
flames or sparks away from the battery area.
Make sure the batteries are charged in a well
ventilated area.
The slave receptacle can be used to charge the batteries
and slave start the engine from an external power source.
The slave receptacle can also be used to charge and
slave other equipment.
CED,OUOE042,62 1907APR991/1
5-4


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.