TM 5-3805-280-10
Operating the Engine
STARTING THE ARCTIC STARTER
Move switch (A) to ON position.
A continuous green on the LED light (B) indicates the
system is operating properly. There is a normal delay of
up to 90 seconds before actual ignition of the heater
burner.
If the LED light (B) flashes green something in the system
sequence did not occur properly and default sensors have
shut down the heater start-up. If this occurs, move switch
(A) to OFF position for 15 seconds and then move switch
to ON position.
If the LED light (B) does not stay a continuous green after
four consecutive tries, move switch (A) to OFF position
and contact maintenance shop.
NOTE: Move switch (A) to ON position for two minutes
with a continuous green LED light (B) once a
month when it is not used. This will prevent the
A--Heater Switch
B--LED Light
CED,OUOE020,14 1901MAR991/1
CHECK INSTRUMENTS AFTER STARTING
IMPORTANT: Prevent possible damage to engine. If
indicator lights do not go out after
starting engine, IMMEDIATELY STOP
THE ENGINE. Find and correct the
problem.
After the engine is started, the indicator lights should go
out. If they do not, stop the engine immediately. Find and
correct the problem.
TX,25,DH3613 1927JUN951/1
5-8