Periodic Maintenance
OPEN ACCESS DOORS FOR SERVICE

Operator Manual For Hydraulic Excavator Model 230Lcr And Model 230Lcrd With Rock Drill
Page Navigation
  178    179    180    181    182  183  184    185    186    187    188  
img
TM 5-3805-280-10
Periodic Maintenance
PREPARE MACHINE FOR MAINTENANCE
Before performing maintenance procedures given in the
following chapters and before leaving the operator's seat,
park the machine as described below unless another
position is specified in the procedure.
1. Park machine on a level surface.
2. Lower bucket to the ground.
3. Turn auto-idle switch off.
IMPORTANT: Turbocharger may be damaged if
engine is not properly shut down.
4. Run engine with engine rpm dial at 1/3 position without
load for 2 minutes.
5. Move engine rpm dial to slow idle position.
6. Turn key switch to OFF. Remove key from switch.
7. Pull pilot control shut-off lever to locked position.
TX,50,DH5079