JT05801 CLAMP-ON ELECTRONIC TACHOMETER INSTALLATION
CHECK AND ADJUST FUEL SHUT-OFF SOLENOID LINKAGE - Continued

Maintenance Manual For Hydraulic Excavator Model 230Lcr
Page Navigation
  121    122    123    124    125  126  127    128    129    130    131  
img
TM 5-3805-280-24-1
Adjustments
CHECK AND ADJUST FUEL SHUT-OFF
SOLENOID LINKAGE
SPECIFICATIONS
Overtravel Needed Distance
3--6 mm (1/8--1/4 in.)
Ball Joint Hole-to-shut-Off Lever
3 turns short
Hole Length
Fuel Shut-Off Solenoid
8 Nm (70 lb-in.)
Plunger-to-Ball Joint Torque
Fuel Shut-Off Lever-to-Run
Less than 0.025 mm (0.001 in.)
9010
Position Stop Clearance
with key switch ON and solenoid
20
plunger bottomed.
2
Shut-Off Lever Clearance
Within 3 mm (0.125 in.) Of Stop
Position Stop
SERVICE EQUIPMENT AND TOOLS
Feeler Gauge
Continued on next page