TM 5-3805-280-24-1
Adjustments
IMPORTANT: Failure to have the shut-off lever tight
against run position stop (upper stop)
9. Turn the key switch to ON.
Push plunger into solenoid housing so hold coil holds
the plunger in the run position.
Check that shut-off lever is tight against run position
stop using a 0.025 mm (0.001 in.) feeler gauge. If
9010
20
feeler gauge passes between shut-off lever and stop,
4
shorten the linkage two more turns.
Fuel Shut-Off Lever-to-Run Position Stop--Specification
Clearance ................................................ Less than 0.025 mm (0.001 in.)
with key switch ON and solenoid
plunger bottomed.
10. Turn key switch to OFF.
The spring inside the solenoid housing boot will
extend the plunger to push the shut-off lever down to
the stop position stop (lower stop) (G).
Check that shut-off lever is within 3 mm (0.125 in.) of
stop position stop.
Shut-Off Lever--Specification
Clearance ................................................ Within 3 mm (0.125 in.) Of Stop
Position Stop
TX,05,GG2305 1922APR983/3
3-43