TRAVEL ALARM CIRCUIT DIAGNOSTIC PROCEDURES - CONTINUED
OVERLOAD ALARM CIRCUIT OPERATIONAL INFORMATION

Maintenance Manual For Hydraulic Excavator Model 230Lcr
Page Navigation
  291    292    293    294    295  296  297    298    299    300    301  
img
TM 5-3805-280-24-1
Sub-System Diagnostics
TRAVEL ALARM (H10)
With harness connector disconnected, connect 24 volts
YES: Alarm is OK.
CHECK
to travel alarm terminal B, and ground terminal C.
NO: Alarm has failed.
Does alarm sound?
Replace.
T8037BB UN30JUN93
1/1
TRAVEL ALARM
YES: Switch and harness
CANCEL SWITCH (S17)
are OK.
9015
CHECK
15
NO: Switch or harness
99
has failed. Repair or
replace.
T118559 UN21NOV98
Turn key switch OFF.
Disconnect harness connector from travel alarm.
Connect ohmmeter from travel alarm harness connector pin A to ground.
Push travel alarm cancel switch.
Is continuity measured when switch is pressed?