HYDRAULIC PUMP REGULATOR TEST AND ADJUSTMENT--ENGINE PULLDOWN - Continued
HYDRAULIC PUMP REGULATOR TEST AND ADJUSTMENT--ENGINE PULLDOWN - Continued

Maintenance Manual For Hydraulic Excavator Model 230Lcr
Page Navigation
  557    558    559    560    561  562  563    564    565    566    567  
img
TM 5-3805-280-24-1
Tests
e. Adjust system relief valve (D):
Run engine at fast idle.
Actuate and hold both propel functions over relief.
Loosen 32 mm nut (H). Turn second adjusting
plug (G) out to obtain 17 235 kPa (172 bar) (2500
psi). Tighten nut.
f. Run engine at fast idle.
g. Actuate and hold both propel functions over relief.
D--System Relief Valve
E--First Adjusting Plug
F--27 mm Nut
G--Second Adjusting Plug
H--32 mm Nut
I--Piston
9025
25
109
Continued on next page
TX,9025,GG2661
1906MAY977/14
6-240