Tests
k. Check the adjustments:
Actuate and hold right propel function over relief.
Engine pulldown must not go below 2080 rpm. If
it does, turn front pump load adjusting cartridge
(L) out until pulldown is 2080--2100 rpm. Record
rpm reading. Release propel function.
Actuate and hold left propel function over relief.
Engine pulldown must not go below 2080 rpm. If
it does, turn rear pump load adjusting cartridge
(L) out until pulldown is 2080--2100 rpm. Record
rpm reading. Release propel function.
The pulldown rpm reading for front and rear
pumps must be within 10 rpm of each other to
prevent machine from mistracking.
l. Make final pump regulator adjustments by observing
how straight the machine tracks under load.