TM 5-3805-280-24-1
Tests
BOOM CYLINDER CONTROLLED LOAD
LOWERING VALVE TEST
SPECIFICATIONS
Circuit Relief Pressure
5400 psi
SERVICE EQUIPMENT AND TOOLS
Gauge 70000 kPa (700 bar) (10000 psi)
AT126362 T-fitting
Test is used to measure circuit relief pressure at the load
lowering valves.
Continued on next page
CED,OUOE020,73 1926MAY991/2
9025
25
137
6-268