REMOVE AND INSTALL FAN AND FAN GUARD
REMOVE AND INSTALL THERMOSTATS

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  616    617    618    619    620  621  622    623    624    625    626  
img
TM 5-3805-280-24-2
Cooling System
REMOVE AND INSTALL FAN BELT
1. Remove fan guard. (See procedure in this group.)
2. Place a 15 mm wrench over the hex head of cap
screw (A) in the center of the tension adjuster idler.
3. Pull idler away from belt (see arrow) to release belt
tension. Remove old belt.
4. Loosen air conditioning compressor (if equipped) and
remove compressor belt from crankshaft pulley.
NOTE: It is not necessary to remove fan to replace fan
belt.
05
5. Remove fan belt.
0510
4
6. Install new fan belt.
7. Fit belt around all pulleys except adjuster idler.
8. Pull adjuster forward and slide belt behind adjuster
idler.
9. Slowly release adjusters.
10. Adjust and tighten compressor belt.
11. Install fan guard.
A--Hex Head of Cap Screw
TX,05,UU3883
1918SEP981/1
14-8