AIR INTAKE SYSTEM LEAKAGE TEST
DISASSEMBLE AND ASSEMBLE AIR CLEANER

Maintenance Manual For Hydraulic Excavator 230Lcr And 230Lcrd With Rock Drill 2
Page Navigation
  636    637    638    639    640  641  642    643    644    645    646  
img
TM 5-3805-280-24-2
Intake System
REMOVE AND INSTALL AIR CLEANER
1. Disconnect wiring connector (A).
2. Loosen clamp (B). Disconnect hose (C).
A--Wiring Connector
B--Clamp
C--Hose
05
0520
4
TX,05,UU3894 1920NOV961/2
3. Remove cap screws, washers, and lock washers (A).
Remove air cleaner.
4. Replace parts as necessary.
5. Install air cleaner.
6. Connect hose. Tighten clamp until hose starts to
deform around clamp band.
Air Cleaner Hose Clamp--Specification
Tighten............................................................. Until hose starts to deform
around clamp band
A--Cap Screws, Washers, and Lock Washers
7. Connect wiring connector.
TX,05,UU3894 1920NOV962/2
14-28